• 1/5

CY-Cube10 High Speed 10mm Galvo Scanner Head with Metal Shell

The 2-axis 10mm galvo scanner head can be used to deflect a laser beam in X and Y directions. This produces a two-dimensional area allowing a laser to be directed at any position. This area is known as the “marking field” as shown in the diagram. Deflection is performed by two mirrors, each of which is moved by a galvanometer scanner. The deflection unit has a beam input, into which the laser beam is fed, and a beam output, through which a laser beam is emitted from the unit after deflection. CY-Cube10 galvo scan head is new design with metal shell and high speed which can be used for fly marking.
Model CY-Cube10
Wavelength 1064nm 532nm 355nm 10600nm
Product Details

1. Input beam aperture: 10mm
2. Good degree of linearity, high resolution small drift, precise repetitive positioning.
3. High speed galvanometer scanning, stable performance small zero drift, strong anti-interference
4. Extensive application: Laser deflection and two-dimensional localization etc.
5. Other wavelengths can be chosen, 10.6um, 1064nm, 355nm, 532nm etc.

20241206


The CY-Cube10 Input Aperture High Speed 10mm Galvo Scanner Head has good running stability, high positioning accuracy, fast marking speed, strong anti-interference ability, the overall performance of the scanner has reached the international leading level in this field.

The advantages are as following:

■ Adopted the photoelectric sensors

■ Differential photoelectric sensor for accurate detection of motor rotor position, good linearity, lower drift, high resolution and repeat positioning.

■ Accurate load design for 10 mm beam aperture mirrors, high accuracy of the motor assembly, reasonable structure, very small static friction coefficient, and zero offsets, all ensured the best dynamic characteristics for the whole system.

■ Drives with advanced detection ability of position and speed greatly improved the dynamic response performance and scanning speed of the whole system.

■ Design of overload, over-current, and reverse connect protection, makes the system running more reliable.

■ The whole system adopted the optimization Designing of electromagnetic compatibility, with a high signal-to-noise ratio and strong anti-interference ability.

■ This galvanometer galvo scan system solved the common problems of motor temperature drift, signal interference, and zero drift, etc.

Model

CY-Cube10

Maximum allowed   average laser power

≤100W

Damage   threshold for pulsed operation

10J/CM²

Aperture

10mm

Effective scan   angle

±15°

Tracking error

≤0.13ms

Step response   time (1% of full scale)

0.20ms

Speed

Positioning /   Jump

<20m/s

Precision   marking speed

<4.0m/s

Good writing   quality

950 cps

Precision

Linearity

0.999

Repeatability

2μrad

Temperature   drift

Over 8 hours long-term   offset drift (after 30 min warm-up)

25μrad

Over 8 hours   long-term gain drift (after 30 min warm-up)

50μrad

Operating   Temperature Range

25 ± 10

Signal   interface

Analog: ± 10 V or ± 5 V

Digital: XY 2 - 100 protocol

Input power requirement   (DC)

± 15 V @ 2A Max RMS